Cooling Tower Specification

  • Refrigerating Capacity
  • Cooling capacity varies from 20 TR to 1000+ TR, based on model
  • Air Flow
  • High-volume axial fan system for large-scale air movement
  • Material
  • Corrosion-resistant FRP (Fibre Reinforced Plastic), galvanized steel structure, PVC fills
  • Application
  • Industrial process cooling, HVAC systems, power plants, manufacturing facilities
  • Motor
  • Heavy-duty, weather-proof electric motor designed for continuous operation
  • Condition
  • New
  • Type
  • Induced Draft / Counterflow / Crossflow Cooling Tower (model dependent)
  • Dimension (L*W*H)
  • Customized as per site requirement, typically ranges from 2m x 2m x 3m upwards
  • Power Supply
  • Three phase, 415V, 50 Hz / Customizable as required
  • Voltage
  • 415V / 380V / 440V (customizable)
  • Cooling Type
  • Evaporative cooling
  • Nozzle Material
  • High-grade polypropylene or brass, corrosion resistant
  • Cooling Coil Material
  • Galvanized steel or stainless steel, as specified
  • Water Flowing Rate
  • (Duplicate entry - see above)
  • Water Pump Motor
  • Matched to tower size, typically 5 HP to 100 HP
  • Noise Control
  • Low noise design with silencers and vibration dampers
  • Compressor
  • Not Applicable (Cooling tower does not use a compressor)
  • Maintenance Access
  • Provision for internal inspection and easy cleaning
  • Inlet Temperature Range
  • Handles inlet water temperatures of up to 60C
  • Drift Eliminator
  • Fitted to minimize water loss
  • Installation Options
  • Field-erected or factory-assembled
  • Service Life
  • Designed for over 15 years with standard maintenance
  • Water Distribution System
  • Uniform rotary sprinkler or fixed header type
  • Fan Type
  • Low-speed axial fan with corrosion protection
  • Fill Media
  • Honeycomb type, high-efficiency heat transfer PVC fills
  • Automation
  • Optional temperature and flow monitoring with PLC controls
  • Operating Environment
  • Outdoor, with UV-resistant construction
 

Cooling Tower Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 1 Unit Per Month
  • Delivery Time
  • 1-2 Week
 

About Cooling Tower



Access a rarefied class of Cooling Towers engineered for first-rate industrial cooling across India's diverse climates. Featuring a low-speed, corrosion-protected axial fan and high-efficiency honeycomb PVC fills, these towers deliver enviable performance with minimal drift loss. Designed for flexible order volumes-from 20 TR to over 1000 TR-each model supports a broad temperature spectrum and field or factory assembly. Their corrosion-resistant FRP and galvanized steel build ensure a service life surpassing 15 years. Popular among manufacturers, power plants, and HVAC applications, these towers reflect the pinnacle of modern, customizable cooling technology.

Competitive Advantages & Usage Type

Our Cooling Towers combine advanced UV-resistant construction and low-noise operation with enviable maintenance access, ensuring seamless inspection and cleaning. The inclusion of drift eliminators and durable honeycomb PVC fill media support rarefied efficiency, while robust automation options provide enviable monitoring and control. Suitable for industrial process cooling, manufacturing, HVAC, and power plants, these units are designed for continuous, high-volume performance-making them the popular choice for first-rate reliability in demanding usage environments.


Delivery Time, Market & Payment Terms

Once we receive your purchase order, typical delivery time for these cooling towers ranges from four to ten weeks, depending on customization and installation requirements. We service the entire Indian market, offering rarefied value through competitive pricing based on precise outlay calculations. Payment terms can be tailored to client needs, generally by advance payment or credit based on agreement-each structure designed to maximize market value and support seamless procurement for buyers and suppliers nationwide.


FAQ's of Cooling Tower:


Q: How does the honeycomb fill media improve cooling tower efficiency?

A: The honeycomb-type PVC fill media offers increased surface area for heat exchange, enhancing water and air contact for first-rate cooling efficiency, particularly in high-temperature environments.

Q: What maintenance access features are included in the tower design?

A: Our cooling towers are equipped with provision for easy internal inspection and thorough cleaning, allowing for regular maintenance and contributing to a service life of over 15 years.

Q: Where can these cooling towers be installed and used?

A: They are ideal for outdoor installation in industrial settings, manufacturing plants, power plants, and HVAC systems, thanks to their robust and corrosion-resistant construction.

Q: What are the primary advantages of corrosion-protected, low-speed axial fans?

A: Low-speed axial fans with corrosion protection deliver high-volume air movement with reduced noise and vibration, providing efficient cooling and extending the operational lifespan of the unit.

Q: When can clients expect delivery after placing a purchase order?

A: Delivery lead time typically ranges from 4 to 10 weeks, depending on model customization, installation option selected, and order volume.

Q: How does the optional automation work in these cooling towers?

A: The PLC-based automation system offers continuous monitoring and precise control of temperature and flow rates, ensuring optimal tower performance and energy efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+